VP 18 M2
VP 18 M2 is an efficient heat recovery unit that can ventilate a dwelling with up to 425 m3/h. The unit is typically used in single-family dwellings. In addition to ventilation and heating of the supply air, it provides guaranteed optimal heating of domestic hot water in the dwelling.
VP 18 M2 is a very compact unit that takes up no more space than an ordinary tall cabinet.
Airflow (see planning data for SEL/SFP values)
Min : 100 m3/hMax : 425 m3/h
Nilan App - Control the ventilation and heat pump directly from the mobile phone
Nilan has developed an App with great features where the user can control the ventilation and heat pump directly from the mobile phone. The App is intuitive, easy and safe to use, and allows the user to e.g. set the room temperature. More ventilation units can be connected using the same App to control the indoor climate in e.g. both the dwelling and the holiday home. More users can be connected the same App. When purchasing a Nilan gateway, the user can access the unit via the Nilan App. |
VP 18 M2
|
CapacityCapacity of standard unit as a function of qv and Pt, ext. SEL values according to EN 13141-7 are for standard units with ISO 16890 Coarse 75% (G4) filters and without heating element. SEL values comprise the unit’s total power comsumption excl. control. Attention! The SEL values are measured and stated as a total value for both fans. |
|
COP (air-air)Heat output factor COP [-] supply air as a function of outdoor temperature t21 [°C] and volume flow qv [m3/h] in accordance with EN14511 at a room temperature t11 = 21°C
|
|
Heat output supply airHeat output Qc [W] as a function of qv [m3/h] and outdoor air temperature t21 [°C]. In accordance with EN 14511, t11=21°C (extract air). Heat output is the contribution to room heating added to the fresh air via VP 18 to the supply air. The ventilation loss is the heat output that is lost without heat recovery at the given volume flow air. |
|
Tapped waterTapped volume in litres Vmax [L] from VP 18 tank as a function of tapped temperature t [C°] and tank temperature at 40°, 50° and 60°C. |
|
Sound dataSounddata is for qv = 210 m3/h and Pt, ext = 100 Pa in accordance with EN 9614-2 for surface and EN 5136 for ducts. Sound output level LWA drops with falling air volumes and falling back-pressure. At a given distance, the sound pressure level LpA will depend on the acoustic conditions at the installation site.
|
All dimensions are in mm. Connections: |
The CTS602 control system is an advanced control system with many settings options. The control system is supplied with factory default settings that can be adapted to the operational requirements in order to achieve best possible operation and utilisation of the unit. The HMI Touch panel provides an overview of the current operation of the unit, and the structure of its menu makes it easy to navigate for both user and installer. External communication
You can find further information about all the functions in the Software and Installation instructions for the unit.
|
ATTENTION! When positioning the unit, you should always consider future services and maintenance. It is recommended that you leave a minimum of 60 cm of clear space in front of the unit. It must be easy to replace filters and it must be possible to replace, for instance, fans and other components. ATTENTION! The unit must be level to enable proper drainage from the condensate tray.
|