Ventilation requirement of up to 175 m3/h.
The Comfort CT150 is for anyone who wants ventilation with highly efficient heat recovery.
Comfort CT150's compact design makes it ideal to use in new and refurbished flats, terraced housing and summer cottages, where the space available is limited and easy fitting is required. The system can be fitted to the ceiling or the wall.
The system extract hot, humid air from e.g. the kitchen, bathroom and utility room, and at the same time remove dust particles, moisture and odours from the home. Furthermore, the energy from the extract air is used to heat the incoming air.
The system can be equipped with supplementary heating coils that can be connected to an electric or central heating system. The systems will produce a comfortable incoming air temperature even in the coldest winter weather. When you buy a Comfort system, you get a comfortable and healthy indoor climate and cost savings on your heating bill.
User selection/Range hood solution
It is also possible to activate user selection mode (Step 4) via a potential-free contact. The set includes a cable with two RJ12 connectors.
Connect the connector at the unit and connect the control panel and the 10 m of cable, for example, to a range hood, ind the two-connectionbox.
User selection/range hood-damper solution
It is also possible to activate user selection mode (Step 4) via a potential-free contact.
The set includes an RJ12 cable, a connection box for the range hood, damper connections as well as a 230V main supply plug.
Fire suppression system
Can be supplied with an integral fire suppression system, for use in apartment blocks with a common discharge air duct and possibly common outdoor air duct.
Spacing bracket, vertical installation
For vertical installation, a wall bracket can be attached to lead and conceal the ducts.
This converts the unit to a top unit.
The side panels are prepared for mounting of the display panel.
Pollen filter F7
A pollen filter class F7 can be fitted in the unit. The pollen filter is fitted with the G4 plate filter.
Spacing bracket, vertical installation
For vertical installation, a wall bracket can be attached to lead and conceal the ducts. This converts the unit to a top unit.
The side panels are prepared for mounting of the display panel.
Electrical pre-heating element (Frost protection)
An electrical pre-heating element heats up the outdoor air before it enters the unit. This avoids having to defrost the unit, resulting in a loss of power.
There are temperature sensors supplied to be fitted in the ducts.
Water heating element incl. regulation (duct mounted)
The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the duct and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat.
Electrical heating surface incl. regulation
When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors.
F7 - Pollen filter
A pollen filter class F7 can be fitted in the unit. The pollen filter is fitted with the G4 plate filter.
EM-box
An EM-box allows heat recovery from the air from the range hood and thereby helps to heat the supply air. The EM-box is equipped with a steel filter which efficiently cleans the range hood air of fat particles and thereby protects the system.
Expansion PCB
The expansion PCB provides additional functions for the CTS 602 control unit, e.g. controlling the EM-box.
Installation kit
The installation kit comprises of four vibration absorbers and a water trap for the condensation outlet. The water trap can be ordered separately.
Comfort CT150 is an energy-efficient ventilation system with heat recovery for homes with a ventilation requirement of up to 175 m3/h. Comfort CT150 is particularly suitable for newly-built or renovated flats, raraced house and summer cottages where the space is limited.
Comfort CT150 is designed for vertical or horizontal mounting, which ensures flexible installation.
Comfort CT150 is factory tested and ready for use. Installation and commissioning must be performed by an authorised electrician.
Dimensions (WxDxH) | 1000 × 524 × 333/338 mm (*1) |
Weight | 30 kg |
Plate type casing | Aluzinc steel plate |
Heat exchanger type | Polystyrene counter flow heat exchanger with aluminium casing |
Fan type | EC, constant rotation |
Filter class | Standard G4 |
Duct connections | Ø 125 mm |
Condensate drain | PVC, Ø 20 × 1.5 mm |
Supply voltage | 230 V (±10 %), 50/60 HZ |
Max. input/power | 53 W / 0.25 A (*4) |
Tightness class | IP31 |
Standby power | 3,4 W |
Ambient temperature | -20/+40 °C |
Lækage klassifikation | A1 (*2) |
Heat loss | 0.96 W/m2K (*3) |
Heat loss classification | T2 |
Ecodesign/ERP data
Fan data | |
Motordata (optimalt driftspunkt) |
*1 338 mm with wall mounting
*2 Testet according to EN13141-7
*3 Testet according to EN1886
Capacity
Capacity of standard unit as a function of qv and Pt, ext.
SEL values according to EN 13141-7 are for standard units with G4 filters and without heating element.
SEL values comprise the unit´s total power comsumption excl. control.
Conversion factor: J/m3 : 3600 = W/m3/h
Temperature efficiency
Temperature efficiency for units with counterflow heat exchanger according to EN308 (dry).
Temperature efficiency EN308:
ɳt = (tsupply air-tfresh air)/(textract air-tfresh air)
Sound data
Sound data for qV = 126 m3/h and Pt, ext = 75 Pa according to EN 9614-2 for surfaces and EN 5136 for ducts.
Sound output level LWA drops with falling air volume and falling back pressure.
Sound output level LpA at a given distance will depend on acoustic conditions in the place of installation.
CTS150 control unit
The CTS150 control unit is a simple control unit used to control the CT150 system. It offers the user only limited access to settings.
Users can adjust the air volume and humidity levels.
The control unit also shows whether the system is working and when an alarm is triggered.
To set and regulate the system, it has to be connected to a PC via a USB flash drive. Download the software from NilanNet and install. The software can be used not only to set the system, but also to read operating data.
CTS602 control unit
Advanced display control panel
The CTS 602 display control panel offers a wide range of different functions, including menu-controlled operation, weekly program settings, timer-controlled filter flow meter, fan speed adjustment, summer bypass (free cooling), heating coil control, error messages, etc.
The CTS 602 factory settings are default settings that can be adapted to the operational requirements, in order to achieve optimum operation and use of the system.
Basic adjustable control panel
The CTS 602 adjustable control panel only allows fan speed adjustment at four different levels.
However, it is possible to adjust settings and view error messages with a Comfort CT150 Service Panel.
Connections
1: Fresh air
2: Supply air
3: Extract air
4: Discharge air
5: Condensate drain
6: Electric and water heating
Automation
T2/T7: Supply air sensor
T9: Heating element
T3: Extract air sensor
T4: Discharge air and defrost sensor
T8: Fresh air sensor
T10: Room sensor
Functional overview CTS150 control
Functional overview |
+Standard -Accessories |
|
Filter monitor | Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. | + |
100 % bypass | Bypassing the outdoor air reduces heat recovery when heat recovery are not needed. | + |
Humidity control | Allows you to set a higher or lower ventilation step in the case of high/low air humidity. | + |
Summer/Winter operation | Possible to set operation for summer and winter. | + |
Winter low | Allows you to select a low ventilation step in the case of low outside temperatures. | + |
Defrost function | Temperature-based automatic function for defrosting the heat exchanger. | |
Temperature control | The system’s overriding temperature sensor is T3 extract air. | + |
Air volume | Allows you to set four ventilation steps stepless. Supply air and extract air are set individually. Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100% |
+ |
User option | It is also possible to activate user selection mode (Step 4) via a potential-free contact. | - |
Functional overview CTS 602 control
Functional overview |
+Standard -Accessories |
|
3 levels | The control function is divided into 3 levels: User/Service/Factory with various options at each level. | + |
Weekly plan | The unit has 3 weekly programmes (with a factory setting of “off”) • Programme 1: for working families • Programme 2: for stay-at-home families • Programme 3: for businesses There is also an option for you to set your own weekly programme. |
+ |
User option 1 | This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. | + |
User option 2 | With an Expansion PCB mounted, allows you to make additional connections, e.g. • User option 2 overrides User option 1 (e.g. connecting an EM box) • Up to 500 W direct • Output relai • Switching the central heating system on/off |
- |
Alarms | Alarm log featuring the last 16 alarms. | + |
Datalog | Possible to log data. Kapacity 46.000 logs • Adjustable between 1 and 120 minutes • If “OFF”, only events and alarms are logged |
+ |
Filter monitor | Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. | + |
Bypass |
Bypassing the outdoor air reduces heat recovery when heat recovery are not needed. | + |
Air quality | Allows you to choose whether to switch humidity sensors and/or CO2 sensors on and off. | +/- |
Humidity control | Allows you to set a higher or lower ventilation step in the case of high/low air humidity. | + |
CO2 control | Allows you to set a higher or lower ventilation step in the case of a high CO2 level. | - |
Summer/Winter operation | Possible to set operation for summer and winter. | |
Winter low | Allows you to select a low ventilation step in the case of low outside temperatures. | + |
Defrost function | Temperature-based automatic function for defrosting the heat exchanger. | + |
Frostprotection | In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. | + |
Temperature control | Allows you to select the temperature sensor which will control the unit. • T15 ROOM (panel sensor) • T10 EXT (fitted in a representative extraction valve) • T3 EXHAUST (extract air) |
+ |
Room low | Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from 1 to 20 degrees and is controlled by: • T15 ROOM (panel sensor) • T10 EXT (fitted in a representative extraction valve) • T3 EXHAUST (extract air) |
+ |
Air volume | Allows you to set four ventilation steps stepless. Supply air and extract air are set individually. Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100% |
+ |
External firealarm | Possible to connect the unit to external firealarm. | |
+ | ||
Joint alarm | Outlet for joint alarm. | - |
Constant pressure control | Allows control from both the extract air and supply air side. | + |
Cooling | Via bypass (can only cool with outdoor temperature) and cool recovery (can only cool with indoor temperature). This allows you to choose whether to run the system at a higher or the highest ventilation step during cooling. The weekly programme has an option for setting cooling at night. |
+ |
Intake air control | Allows you to set the regulator to control the intake air temperature/supply air (only available if the control unit has been configured for a supply-heating element). |
- |
External heating element | • Temperature sensor T7 is an supply air sensor • Integrated frost protection for external water heating element • Motorised valve and circulation pump control unit |
+ |
External electric heating element | • Temperature sensor T7 is an supply air sensor • Overheating protection |
+ |
Delayed start-up | There is a possibility for a delayed start-up by the fans, when a closing damper is installed. | + |
Reset | Allows you to restore the factory settings. | + |
Manual test | Allows you to test the unit’s functions manually. | |
Language | Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/French). |
SEC* average climate | - 42.7 kWh/(m2.a) |
SEC* cold climate | - 82.1 kWh/(m2.a) |
SEC* warm climate | - 17.5 kWh/(m2.a) |
SEC-Class | A+ |
Type | Residential ventilation unit |
Type of drive | Variable speed drive |
Type of heat recovery system | Recuperative (counterflow heat exchanger) |
Thermal efficiency of heat recovery |
91.9 % |
Maximum flow rate | 175 m3/h (100 Pa) |
Electric power input of fan drive, including any motor control equipment, at maximum flow rate | 55.7 W |
Sound power level (LWA) | 49 dB(A) |
Reference flow rate | 0.034 m3/s (122,5 m3/h) |
Reference pressure difference | 50 Pa |
SPI | 0.163 W/(m3/h) |
Central demand control | 0.85 |
Maximum internal leakage | 0.19 % |
Maximum external leakage | 0.35 % |
Visual filter warning | A yellow light flashes on the user panel when filters need changing. To maintain the performance and energy efficiency of the unit it is very important to change filters regularly. |
Disassembly instructions | www.nilan.dk |
* Specific energy consumption
AEC - annual electricity consumption | 192 kWh/year (100 m2) |
AHS** average climate | 4681 kWh (100 m2) |
AHS** cold climate | 9157 kWh (100 m2) |
AHS** warm climate | 2117 kWh (100 m2) |
** Annual heating saved