Compact P EK

Ventilation requirement of up to 300 m3/h.

Compact P EK has the same features and benefits as the Compact P, but can also use the energy stored in the ground to heat your home.

The advantage of Compact P EK is that it does not require buried geothermal coils, or the installation of an air extraction heat pump, which is the case for traditional heat-pump based heating solutions. This makes installation easier and less expensive.

Compact P EK is also available in a version with a built-in pre-heating element – Compact Polar EK. Compact Polar EK is optimum for use in cold climates.

Top cover

To cover the ducting over the unit, Nilan offers a top cover in white-varnished aluzinc (RAL 9016).

Solar

Extra heat exchanger of 0.7 m2 in the hot water tank, which can be connected to an approximately 3 m2 solar heating system, or other heat sources.

CO2-sensor

With a CO2-sensor installed, the ventilation speed can be pre-programmed with CTS 602 to run at a higher ventilation steps when CO2 reaches high level in the extract air. CO2-level is programmable.

Pollen filter F7

A pollen filter class F7 can be fitted in the unit. The pollen filter is fitted with the G4 plate filter.

Electrical heating surface incl. regulation

When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors.  

Water heating element incl. regulation (duct mounted)

The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the duct and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat.

The Compact P EK unit has a built-in electrical boiler that can be connected to a waterborne central heating system, thereby providing electrical heating to the home.

The advantage of Compact P EK is that it does not require buried geothermal coils, or the installation of an air extraction heat pump, which is the case for traditional heat-pump based heating solutions. This makes installation easier and less expensive.

Electrical heating is a good solution for very well-insulated homes that do not use a lot of energy for heating, such as passive buildings. However, it must be checked whether electrical heating is legally permitted.

Ecodesign/ERP data

Fan data
Motordata (optimalt driftspunkt)

Compact P EK 3 kW

Heat output 3 kW
Supply voltage 230 V / 3 x 230V / 3 x 400V
Max. fuse size (1 x 230 V) 16 A
Max. fuse size (3 x 230 V) 13 A
Max. fuse size (3 x 400V) 13 A
Weight (electrical boiler) 21 kg
Standby electricity consumption 2 W
Expansion vessel 10 l

Compact P EK 6 kW

Heat output 6 kW
Supply voltage 230 V / 3 x 230V / 3 x 400V
Max. fuse size (1 x 230 V) 16 A
Max. fuse size (3 x 230 V) 13 A
Max. fuse size (3 x 400V) 13 A
Weight (electrical boiler) 21 kg
Standby electricity consumption 2 W
Expansion vessel 10 l

Compact P EK 9 kW

Heat output 9 kW
Supply voltage 230 V / 3 x 230V / 3 x 400V
Max. fuse size (3 x 230 V) 13 A
Max. fuse size (3 x 400V) 13 A
Weight (electrical boiler) 21 kg
Standby electricity consumption 2 W
Expansion vessel 10 l

1 Flow from electrical kettle 3/4”
2 Return flow electrical kettle 3/4”
3 Cold water intake 3/4”
4 Hot water outlet 3/4”
5 Sensor pouch 3/4”
6 Connection for circulation pipe 3/4”
7 Discharge air
8 Supply air
9 Outdoor air
10 Extract air

All dimensions are in mm

1 Connection 3/4”
2 Stop valve
3 Circulation pump
4 Fill valve 1/2”
5 Electrical kettle with electrical heating element
6 Pressure expansion vessel
7 Automatic vent
8 Temperature sensor
9 Manometer
10 Safety valve 2,5 bar
11 Particulate filter

Functional overview CTS 700 control panel

Functional overview  

 +Standard 

-Accessories

3 levels The control function is divided into 3 levels: User/Super user/Installer/Factory with various options at each level.  +
Weekly plan There is an option for you to set your own weekly programme.  +
User option 1 This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor.  +
User option 2 This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. User option 2 has a higher priority than user option 1. +
User option 2 out When user option 2 is used, at the same time an output signal is given. +
Alarms The alarm list is featuring all alarms. +
Datalog Opportunity for datalog.  
Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days.  +
100% Bypass Bypassing the outdoor air reduces heat recovery, enabling the desired supply air temperature to be maintained spring, summer and autumn. +
Air quality Allows you to choose whether to switch humidity sensors and/or CO2 sensors on and off.  +/-
Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity.  +
CO2 control Allows you to set a higher or lower ventilation step in the case of a high/low CO2-level. -
Air exchange Allows you to select a low ventilation step in the case of low outside temperatures and air humidity. +
Night setback A possibility to set back the ventilation and temperature a night. +
Defrost function Temperature-based automatic function for defrosting the heat exchanger. +
Frostprotection In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. +
Temperature control Allows you to select the temperature sensor which will control the unit.
•     TExt external room temperature sensor
•     T3 EXHAUST (extract air)
-
+
Air volume Allows you to set the ventilation flow stepless from 20 to 100 %. In four steps. +
Summer/Winter operation The unit automatically changes to summer or winter operation. +
Legionella control It is possible to choose a weekday or a day during the month, where the sanitary hot water temperature reaches 65 °C, for example between 1 and 6 o´clock. +
Fire alarm This allows you to connect fire-detecting thermostats, smoke detectors and other fire alarm contacts. In case of an alarm, smoke dampers are closed and the unit stops. +
Joint alarm Outlet for joint alarm. +
Cooling Via bypass or heat pump.
The heat pump has a reversible circuit, which means that the units circuit is  reversed and the unit cools, rather than heating, the supply  air. It is possible to choose whether the unit is to run a higher or highest ventilation stage during cooling.
Via a weekly plan night cooling can be set up.
+
External heating element •     Temperature sensor T7 is an supply air sensor
•     Integrated frost protection for external water heating element
•     Motorised valve and circulation pump control unit
-
External electric heating element •     Temperature sensor T7 is an supply air sensor
•     Overheating protection
-
External network It is possible to connect the unit to an external network. +
Reset Allows you to restore the factory settings.  +
Language Option for setting the relevant language (Danish/German/English).  +

 

Model EK 3 kW
Condensing boiler No
Low temperature boiler No
B1 boiler No
Cogeneration space heater No
Combination heater No

 

Item Symbol Value Unit   Item Symbol Value Unit
     
Rated heat output Prated 2,914 kW   Seasonal space heating
energy efficiency
ŋs 39 %
     
At rated heat output and
high-temperature regime
P4 2,914 kW   At rated heat output and
high-temperature regime
ŋ4 39 %
          Other items
          Standby heat loss Pstby 0,0864 kW

 

Model EK 6 kW
Condensing boiler No
Low temperature boiler No
B1 boiler No
Cogeneration space heater No
Combination heater No

 

Item Symbol Value Unit   Item Symbol Value Unit
     
Rated heat output Prated 5,914 kW   Seasonal space heating
energy efficiency
ŋs 39 %
     
At rated heat output and
high-temperature regime
P4 5,914 kW   At rated heat output and
high-temperature regime
ŋ4 39 %
          Other items
          Standby heat loss Pstby 0,0864 kW

 

Model EK 9 kW
Condensing boiler No
Low temperature boiler No
B1 boiler No
Cogeneration space heater No
Combination heater No

 

Item Symbol Value Unit   Item Symbol Value Unit
     
Rated heat output Prated 8,914 kW   Seasonal space heating
energy efficiency
ŋs 40 %
     
At rated heat output and
high-temperature regime
P4 8,914 kW   At rated heat output and
high-temperature regime
ŋ4 40 %
          Other items
          Standby heat loss Pstby 0,0864 kW